# GDP Deployment Notes
4 1 Ken Lutz
5 16 Ken Lutz
## Data users email list created
6 15 Ken Lutz
If you would like to be notified of data anomalies or changes in the sensor actuator send an email to lutz@berkeley.edu asking to be added to the email list, swarm-gdp-data-users@lists.eecs.berkeley.edu
7 15 Ken Lutz
8 38 Eric Allman
## Conventions
9 38 Eric Allman
Unless otherwise noted, the name of the corresponding logs are derived from the physical location (currently `bwrc` or `swarmlab`) and the lowercase MAC address:
10 13 Nitesh Mor
11 13 Nitesh Mor
    edu.berkeley.eecs.<location>.device.<mac-addr>
12 13 Nitesh Mor
13 1 Ken Lutz
For example, a sensor with MAC address `C0:98:E5:30:00:03` in the immersion room (which is in swarmlab) will be named `edu.berkeley.eecs.swarmlab.device.c098e5300003`
14 1 Ken Lutz
15 81 Eric Allman
## Adding Sensors and Gateways
16 38 Eric Allman
See [[Provisioning Sensors]] for instructions on how to add new sensors.
17 39 Nitesh Mor
18 39 Nitesh Mor
See [[Configuring Gateways]] for information about setting up gateway hosts (typically either BBBs or SwarmBoxes).
19 39 Nitesh Mor
20 57 Nitesh Mor
## Visualization
21 82 Nitesh Mor
A minimal visualization tool is [Here](http://swarmnuc1022.eecs.berkeley.edu/static/). Note that the list of sensors is manually updated for the moment, so it may not show all the sensors listed below.
22 57 Nitesh Mor
23 38 Eric Allman
## Deployments
24 38 Eric Allman
25 38 Eric Allman
### BWRC Server Room
26 40 Nitesh Mor
27 1 Ken Lutz
**Sensors and Gateways**
28 41 Nitesh Mor
29 40 Nitesh Mor
* BBB - UHKBBB004.eecs.berkeley.edu 128.32.63.176
30 40 Nitesh Mor
* Rear Wall BLEE - C0:98:E5:30:00:36 
31 40 Nitesh Mor
* Mid Wall BLEE - C0:98:E5:30:00:5D
32 40 Nitesh Mor
* Hot Aisle BLEE- C0:98:E5:30:00:54
33 40 Nitesh Mor
* Lab Rear Wall BLEE - C0:98:E5:30:00:09
34 40 Nitesh Mor
* BLINK - C0:98:E5:90:00:1E
35 40 Nitesh Mor
* Power Blade - Utility power to sump pump - C0:98:E5:70:00:8F
36 40 Nitesh Mor
* Power Blade - Utility power to Air Compressor - C0:98:E5:70:00::90
37 40 Nitesh Mor
* USB Microphone - mounted on BBB
38 75 Ken Lutz
39 61 Ken Lutz
* I3 Sensor tag Mid Wall
40 61 Ken Lutz
* I3 Sensor tag, Lab rear wall
41 23 Ken Lutz
42 23 Ken Lutz
### BWRC Office Area
43 23 Ken Lutz
44 42 Nitesh Mor
#### Sensors and Gateways
45 23 Ken Lutz
46 40 Nitesh Mor
* Swarmnuc1002.eecs.berkeley.edu
47 40 Nitesh Mor
* BLEE
48 40 Nitesh Mor
    - Main seating area - C0:98:E5:30:00:A5
49 40 Nitesh Mor
    - Conference Room , Rabaey Room - C0:98:E5:30:00:A3
50 40 Nitesh Mor
    - Admin Office - C0:98:E5:30:00:A4
51 40 Nitesh Mor
    - Conference Room - Brodersen room - C0:98:E5:30:00:A2
52 40 Nitesh Mor
    - Ken's Office  - C0:98:E5:30:00:A1
53 40 Nitesh Mor
    - Brian Office above thermostat - C0:98:E5:30:00:A0
54 40 Nitesh Mor
    - Center of student seating area, above thermostat - C0:98:E5:30:00:37
55 40 Nitesh Mor
* Blink
56 40 Nitesh Mor
    - Brodersen Conference Room C0:98:E5:90:00:87
57 1 Ken Lutz
    - Rabaey Conference room -  C0:98:E5:30:00:94
58 75 Ken Lutz
59 75 Ken Lutz
*I3 Mesh Network uhkbbb011 Host
60 75 Ken Lutz
* I3 Mesh root node 
61 75 Ken Lutz
 - S/A 3:  EUI: 00-12-4b-00-0a-4a-b9-05 
62 75 Ken Lutz
 - S/A 4: EUI: 00-12-4b-00-0a-63-0c-81
63 75 Ken Lutz
 - S/A 5: EUI: 00-12-4b-00-0a-4a-58-02
64 75 Ken Lutz
 - S/A 6: EUI: 00-12-4b-00-0a-4b-38-83
65 75 Ken Lutz
 - S/A 7: EUI: 00-12-4b-00-0a-55-c3-02
66 75 Ken Lutz
 - S/A 8: 
67 75 Ken Lutz
 - S/A 9: EUI: 00-12-4b-00-0a-64-aa-04
68 75 Ken Lutz
 - S/A 10: EUI: 00-12-4b-00-0a-55-33-86
69 75 Ken Lutz
 - S/A 11: EUI: 00-12-4b-00-07-91-3c-82
70 75 Ken Lutz
 - S/A 12: EUI: 00-12-4b-00-0a-4c-58-80
71 75 Ken Lutz
 - S/A 13: EUI: 00-12-4b-00-0b-23-45-83
72 75 Ken Lutz
73 75 Ken Lutz
74 17 Ken Lutz
75 29 Ken Lutz
76 40 Nitesh Mor
**Operational Notes**
77 17 Ken Lutz
78 40 Nitesh Mor
* 6-17-16 2:59PM Repaired broken Blink in server room. Was reading all zero, now detecting movement correctly.
79 40 Nitesh Mor
* 7/11/16 Fixed powerblade on air compressor - was installed backward. Data collected after 7/11 looks correct. Prior was in error. Note that energy accumulated goes to zero when powerblade was disconnected for inspection. Good marker. 
80 40 Nitesh Mor
* 7/14/16 9:29AM Correlated spike in temperature and humidity for a short period of time across all BLEES in the server room. Probably related to someone working in the room and having propped the door open.
81 40 Nitesh Mor
* 7/17/16-7/19/16: Missed about 2 days worth of data due to bug in the MQTT-gateway. 
82 40 Nitesh Mor
* 7/19/16 4:05 PM - 4:19PM: Put a cover over the Lab Rear wall BLEE causing the light level to go to zero. Temp and humidity are down as well.
83 40 Nitesh Mor
* 7/19/16 4:20PM - 4:31PM: Put a cover over BLEE in server room, mid wall. Light level goes to zero, temp goes up. Other sensors in the server room do not show similar readings
84 40 Nitesh Mor
* 7/25/16 - Added sensors and gateway to BWRC office area. New batteries
85 40 Nitesh Mor
* 8/1/16 BBB004 down for maintenance 2-5pm.
86 40 Nitesh Mor
* 8/8/2016 Replaced batteries in server room  and Kens office
87 40 Nitesh Mor
* 8/8/16 Removed test powerblade from air compressor outlet strip
88 49 Ken Lutz
* 8/26/16  9:40AM - 10:10am covered light sensor on BLEE in Ken's office - C0:98:E5:30:00:A1
89 52 Ken Lutz
* 8/26/16 11:42 -  Covered light sensor on BLEE Center of student seating area, above thermostat - C0:98:E5:30:00:37
90 52 Ken Lutz
* 8/26/16 12:30 -12:45 (approx) increased humidity on BLEE Brian Office above thermostat - C0:98:E5:30:00:A0
91 52 Ken Lutz
* 8/26/16 2:41-2:47pm increased humidity on  Rear Wall BLEE - C0:98:E5:30:00:36 
92 59 Ken Lutz
* 9/16/16 11:41AM Replaced batteries in server room,  Kens office, student area+
93 61 Ken Lutz
* 10/10/16 12:00 pm Senor tags deployed in server room and rear wall of lab
94 74 Ken Lutz
* 11/28/16 4:35 pm all batteries changed, BLE and Sensor tags
95 78 Ken Lutz
* 2/6/17 1:54 PM Sensor Tag Batteries replaced
96 79 Ken Lutz
* 2/12/17 I3 mesh node firmware updated to V3
97 51 Ken Lutz
98 38 Eric Allman
### Cory Hall Swarm Lab and Immersion Room
99 2 Ken Lutz
**Servers and Sensors**
100 38 Eric Allman
101 38 Eric Allman
#### Immersion Room
102 43 Nitesh Mor
103 43 Nitesh Mor
* Primary projector PowerBlade ~~C0:98:E5:70:00:2B~~ C0:98:E5:70:00:8D
104 43 Nitesh Mor
* Secondary projector PowerBlade C0:98:E5:70:00:8B
105 43 Nitesh Mor
* Speaker Camera PowerBlade C0:98:E5:70:00:8E
106 43 Nitesh Mor
* Audience Camera PowerBlade C0:98:E5:70:00:88
107 43 Nitesh Mor
* BLEE, rear camera pillar C0:98:E5:30:00:03
108 43 Nitesh Mor
* Front wall adjacent to screen Blink C0:98:E5:90:00:0A
109 43 Nitesh Mor
* UHKBBB001.eecs.berkeley.edu 128.32.33.236
110 76 Ken Lutz
* S/T EUI: 00-12-4b-00-07-91-0e-03, S/A 10 (Rear Pillar)
111 33 Ken Lutz
112 33 Ken Lutz
Chair BLEES C0:98:E5:30:0:  {58, 5c, 5F, 7a, 7b, 74, 75, 76, 77, 78}
113 1 Ken Lutz
114 38 Eric Allman
#### Entrance Lobby
115 1 Ken Lutz
116 44 Nitesh Mor
* Swarm Lab Inside Entrance Lobby
117 44 Nitesh Mor
* Blink C0:98:E5:90:00:0B
118 44 Nitesh Mor
* BLEE C0:98:E5:30:00:0A
119 76 Ken Lutz
* S/T EUI: 00-12-4b-00-07-90-75-83, S/A 8 (Pillar)
120 76 Ken Lutz
* S/T EUI: 00-12-4b-00-07-91-15-82, S/A 7 (entrance door)
121 33 Ken Lutz
122 38 Eric Allman
#### Office 490B
123 1 Ken Lutz
124 45 Nitesh Mor
* UHKBBB002.eecs.berkeley.edu
125 76 Ken Lutz
* S/T (Eng Version) EUI: 00-12-4b-00-0d-7d-fa-07, S/A 3 (Kens desktop)
126 76 Ken Lutz
127 76 Ken Lutz
#### Student Area
128 76 Ken Lutz
S/T EUI: 00-12-4b-00-0a-63-62-86,  S/A 6 (Nitesh Desk)
129 76 Ken Lutz
S/T EUI: 00-12-4b-00-0a-55-3b-05, S/A 9 (Wall near Mark Desk)
130 45 Nitesh Mor
131 1 Ken Lutz
#### 4th floor Elevator Lobby
132 1 Ken Lutz
133 45 Nitesh Mor
* Blink C0:98:E5:90:00:91
134 45 Nitesh Mor
* SwarmBox swarmnuc1020.eecs.berkeley.edu
135 45 Nitesh Mor
136 1 Ken Lutz
#### Exit Stair Door near 490
137 11 Ken Lutz
138 45 Nitesh Mor
* Blink C0:98:E5:90:00:19
139 2 Ken Lutz
140 1 Ken Lutz
**Operational Notes**
141 46 Nitesh Mor
142 45 Nitesh Mor
- 7/12/16 2:59PM, powerblade on Speaker camera disconnected for inspection and reconnected. Note that accumulated energy goes to zero at this time. 
143 45 Nitesh Mor
- 7/13/16 10AM, powerblade on Immersion room primary projector re-installed, now in correct orientation. Readings from 10am on look correct.
144 45 Nitesh Mor
- 7/14/16 9:22:58AM - Introduced an anomaly by heating the Immersion room BLEE located on the rear pillar with a hot air gun for about 4 min. Temperature and humidity impacted.
145 45 Nitesh Mor
- 7/14/16 9:46AM - Speaker camera was left on since 7/12 2:26pm. Turned off at 7/14 9:46AM
146 45 Nitesh Mor
- 7/15/16 - 9:40AM Primary projector powerblade seems to have a loose connection. No readings from 7/14 3:23PM until re-seated at 7/15 9:40AM
147 45 Nitesh Mor
- 7/18/16 - 11:30AM BLEES installed on conference table chairs w/ new batteries
148 45 Nitesh Mor
- 7/17/16-7/19/16: Missed about 2 days worth of data due to bug in the MQTT-gateway.
149 45 Nitesh Mor
- 7/19/16: Beaglebone gateway is got powered off. Last data collected was around 4:56PM. Restarted at 10:50PM
150 45 Nitesh Mor
- 7/20/16: Rear Camera pillar BLEE - Battery replaced 3:26PM
151 45 Nitesh Mor
- 7/26/16 Main projector power blade failed - replaced with new unit (new MAC)
152 45 Nitesh Mor
- 8/1/16 BBB001 down for maintenance
153 45 Nitesh Mor
- 8/8/16 Batteries replaced in all sensors except chairs
154 63 Ken Lutz
-10/10/16 Batteries replaced in all Mich sensors
155 63 Ken Lutz
- 10/12/16 Batteries replaced in all TI sensor tags
156 77 Ken Lutz
- 2/6/17 AA Batteries added to Sensor Tags
157 79 Ken Lutz
- 2/11/17 I3 mesh node firmware updated to V3
158 38 Eric Allman
159 38 Eric Allman
### Jacobs Hall
160 47 Nitesh Mor
161 1 Ken Lutz
**Gateways**
162 1 Ken Lutz
163 47 Nitesh Mor
- ~~ML-100 - swarmnuc1005.eecs.berkeley.edu B8:AE:ED:74:09:3D was port 10D-120C-03F10-D room 120~~
164 47 Nitesh Mor
- BBB - uhkbbb005.eecs.berkeley.edu port 10D-332-04F17-D Room 332
165 47 Nitesh Mor
- BBB uhkbbb006.eecs.berkeley.edu 54:4a:16:e0:8b:a1 10D-120C-03F10-D room 120
166 47 Nitesh Mor
- BBB uhkbbb007.eecs.berkeley.edu  6c:ec:eb:5c:64:5b Room 10 10D-10B-02f16-D
167 47 Nitesh Mor
168 1 Ken Lutz
#### Room 110
169 47 Nitesh Mor
170 1 Ken Lutz
**Powerblades**
171 1 Ken Lutz
172 47 Nitesh Mor
- c0:98:e5:70:01:13 Type A 3D printer 10026	room 110
173 47 Nitesh Mor
- c0:98:e5:70:01:22
174 47 Nitesh Mor
- c0:98:e5:70:01:23 Type A 3D printer 10047	room 110
175 47 Nitesh Mor
- c0:98:e5:70:01:25
176 47 Nitesh Mor
- c0:98:e5:70:01:26 Laser 2                                room 110C
177 47 Nitesh Mor
- c0:98:e5:70:01:27 Type A 3D printer 10097	room 110
178 47 Nitesh Mor
- c0:98:e5:70:01:29 Type A 3D printer 10213	room 110
179 47 Nitesh Mor
- c0:98:e5:70:00:e2 Laser 1	                                room 110C
180 47 Nitesh Mor
- c0:98:e5:70:00:e5 Type A 3D printer 10035	room 110
181 47 Nitesh Mor
- c0:98:e5:70:00:d3 Type A 3D printer 10098	room 110
182 47 Nitesh Mor
- c0:98:e5:70:00:d7 Type A 3D printer 10025	room 110
183 47 Nitesh Mor
- c0:98:e5:70:00:f7 Type A 3D printer 10038	room 110
184 47 Nitesh Mor
- c0:98:e5:70:00:db - Type A 3D printer 10094 room 110
185 47 Nitesh Mor
- c0:98:e5:70:01:31 Type A 3D printer 10034	room 110	
186 47 Nitesh Mor
187 1 Ken Lutz
**BLEE**
188 1 Ken Lutz
189 47 Nitesh Mor
- c0:98:e5:30:00:57 room 110 by thermostst
190 47 Nitesh Mor
- c0:98:e5:30:00:55  check placement in room
191 1 Ken Lutz
192 47 Nitesh Mor
193 1 Ken Lutz
#### Room 332
194 19 Ken Lutz
195 34 Ken Lutz
**PowerBlades**
196 38 Eric Allman
197 47 Nitesh Mor
- c0:98:e5:70:00:8a Carbon 3D printer              room 332
198 47 Nitesh Mor
- c0:98:e5:70:01:0c Dimension 2 (Bonnie)	room 332
199 47 Nitesh Mor
- c0:98:e5:70:01:2e Dimension 1 (Clyde)         room 332
200 47 Nitesh Mor
201 4 Ken Lutz
**BLEE**
202 19 Ken Lutz
203 47 Nitesh Mor
- c0:98:e5:30:00:55 room 120
204 47 Nitesh Mor
- c0:98:e5:30:00:50 room 332 Fortus 380 air exhaust vent
205 47 Nitesh Mor
- c0:98:e5:30:00:51 room 332 center of room
206 19 Ken Lutz
207 32 Ken Lutz
**Blink**
208 32 Ken Lutz
209 47 Nitesh Mor
- c0:98:e5:90:00:85 room 332
210 47 Nitesh Mor
- c0:98:e5:90:00:94
211 47 Nitesh Mor
- c0:98:e5:90:00:87
212 47 Nitesh Mor
213 19 Ken Lutz
#### Room 10C
214 38 Eric Allman
**Blink**
215 47 Nitesh Mor
216 47 Nitesh Mor
- c0:98:e5:90:00:81 - wood shop room 10C
217 47 Nitesh Mor
218 34 Ken Lutz
**BLEE**
219 4 Ken Lutz
220 47 Nitesh Mor
- c0:98:e5:30:00:62 room 10C Woodshop
221 2 Ken Lutz
222 47 Nitesh Mor
223 30 Eric Allman
**Operational Notes**
224 47 Nitesh Mor
225 47 Nitesh Mor
- Sensors installed, new batteries 7/15/16
226 30 Eric Allman
227 58 Eric Allman
### TAMU
228 54 Syed Hasnain
edu.tamu.esp.Setup1c.device.*
229 53 Syed Hasnain
230 53 Syed Hasnain
**BLEE**
231 53 Syed Hasnain
c098e530001d
232 53 Syed Hasnain
233 53 Syed Hasnain
**Blink**
234 53 Syed Hasnain
c098e590010
235 53 Syed Hasnain
c098e590011
236 53 Syed Hasnain
c098e590012
237 53 Syed Hasnain
c098e5900ac
238 53 Syed Hasnain
239 53 Syed Hasnain
**PowerBlade**
240 53 Syed Hasnain
c098e5700028
241 53 Syed Hasnain
c098e57000c4
242 53 Syed Hasnain
c098e57000a8
243 53 Syed Hasnain
244 55 Syed Hasnain
245 55 Syed Hasnain
There is also a Motion sensors placed on door. The format is JSON and provides three axis accelrometer, gyroscope, mangnometer and time stamp. The log for the sensor is:
246 55 Syed Hasnain
247 55 Syed Hasnain
edu.esp.Tamu.device.MotionNetBKP
248 55 Syed Hasnain
249 53 Syed Hasnain
**Notes**
250 56 Syed Hasnain
The sensors have been placed in the graduate office space. The power blades are connected to power cords in use by students.